Class=1 (0x01) Alarm functionality

CLASS1.ALARM

Description

Alarm events that indicate that something not ordinary has occurred. Note that the priority bits can be used as a mean to level alarm for severity.

Type = 0 (0x00) Undefined

Undefined alarm.

Type = 1 (0x01) Warning

Indicates a warning condition.

Data byte Description
0 0=off. 1=on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

If both or one of zone/sub-zone are omitted they should be interpreted as if they where 255.

Type = 2 (0x02) Alarm occurred

Indicates an alarm condition.

Data byte Description
0 0=off. 1=on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

If both or one of zone/sub-zone are omitted they should be interpreted as if they where 255.

Type = 3 (0x03) Alarm sound on/off

Alarm sound should be turned on or off.

Data byte Description
0 0=off. 1=on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

If both or one of zone/sub-zone are omitted they should be interpreted as if they where 255.

Type = 4 (0x04) Alarm light on/off

Alarm light should be turned on or off.

Data byte Description
0 0=off. 1=on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

If both or one of zone/sub-zone are omitted they should be interpreted as if they where 255.

Type = 5 (0x05) Power on/off

Power has been lost or is available again.

Data byte Description
0 0=off. 1=on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

If both or one of zone/sub-zone are omitted they should be interpreted as if they where 255.

Type = 6 (0x06) Emergency Stop

Emergency stop has been hit/activated. All systems on the zone/sub-zone should go to their inactive/safe state.

Data byte Description
0 0=off. 1=on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

If both or one of zone/sub-zone are omitted they should be interpreted as if they where 255.

Type = 7 (0x07) Emergency Pause

Emergency pause has been hit/activated. All systems on the zone/sub-zone should go to their inactive/safe state but preserve there settings.

Data byte Description
0 0=off. 1=on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all subzones.

If both or one of zone/sub-zone are omitted they should be interpreted as if they where 255.

Type = 8 (0x08) Emergency Reset

Issued after an emergency stop or pause in order for nodes to reset and start operating .

Data byte Description
0 0=off. 1=on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

If both or one of zone/sub-zone are omitted they should be interpreted as if they where 255.

Type = 9 (0x09) Emergency Resume

Issued after an emergency pause in order for nodes to start operating from where they left of without resetting their registers .

Data byte Description
0 0=off. 1=on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

If both or one of zone/sub-zone are omitted they should be interpreted as if they where 255.

Type = 10 (0x0A) Arm

Issued after an alarm system has been armed.

Data byte Description
0 0=off. 1=on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

If both or one of zone/sub-zone are omitted they should be interpreted as if they where 255.

Type = 11 (0x0B) Disarm

Issued after an alarm system has been disarmed.

Data byte Description
0 0=off. 1=on.
1 Zone for which event applies to (0-255). 255 is all zones.
2 Sub-zone for which event applies to (0-255). 255 is all sub-zones.

If both or one of zone/sub-zone are omitted they should be interpreted as if they where 255.